Rules & Regulations
Scaffold Tower Integration
Before Erecting the Tower
Check all components are in good condition.
Check wheels for effective rotation.
Check brakes and locking devices work correctly.
Before erecting a tower on a suspended floor, ensure the bearing capacity of the floor is sufficient for the planned load.
Before Use
Ensure the tower is vertical and square.
Towers must not be used unless the wheels are locked.
Check that outriggers are set correctly and secured.
Ensure the platform is fully boarded out and that guardrails and toe boards are fitted if the working platform is over 2 metres high.
The gap between toe boards and mid guardrails, and between mid and top guardrails, must not exceed 470 mm.
Stability
Never climb up the outside of a tower. Use the stairway or ladder on the inside.
Follow the manufacturer’s instructions on base-to-height ratio.
Hoist materials up from the inside of the tower.
Do not move the tower if people or materials are still on the platform.
Do not pull the tower along while standing on it.
Towers must only be used on firm, flat surfaces.